 :series_index: 2
 
 After a `quick repair of the PSU of my Tek 2445
-<{static}/TeK2445.rst>`_, I've started a more systematic replacement
+<{filename}/TeK2445.rst>`_, I've started a more systematic replacement
 of the capacitors.
 
 .. image:: {static}/images/tek2445/psu_caps_replaced.jpg
@@ -59,7 +59,7 @@
 
 .. image:: {static}/images/tek2445/dead_transistors.jpg
    :alt: Q1050, 1060 and Q1070 are dead.
-      
+
 For now, I've picked up a 3W 100Ω resistor and I've made a self by
 hand. As I don't have a RLC meter, I don't known its exact value so
 I've took a few measures of its impedance at several frequencies, and
@@ -156,4 +156,3 @@
 While waiting for my DS0026 spare ICs, I'm trying to figure how I can
 elaborate a setup in which I am able to test the PSU without risking
 its life again. I'll have to find my variac in my cellar, I guess.
-