content/TeK2445.rst

changeset 128
aba381b2bac9
parent 115
6b6e13653348
equal deleted inserted replaced
126:521c35556177 128:aba381b2bac9
13 tired PSU: unstable display, noise, then the typical noise of a 13 tired PSU: unstable display, noise, then the typical noise of a
14 capacitor failure. 14 capacitor failure.
15 15
16 Here is the beast: 16 Here is the beast:
17 17
18 .. image:: {static}images/tek2445/tek2445.jpg 18 .. image:: {static}/images/tek2445/tek2445.jpg
19 :alt: My old Tektronics 2445 scope 19 :alt: My old Tektronics 2445 scope
20 20
21 And some pictures of its womb: 21 And some pictures of its womb:
22 22
23 .. image:: {static}images/tek2445/tek2445_A1.jpg 23 .. image:: {static}/images/tek2445/tek2445_A1.jpg
24 :alt: The main analog board. 24 :alt: The main analog board.
25 25
26 .. image:: {static}images/tek2445/tek2445_top.jpg 26 .. image:: {static}/images/tek2445/tek2445_top.jpg
27 :alt: Top view of the scope. 27 :alt: Top view of the scope.
28 28
29 The PSU consists in two PCBs coupled with long jumpers. It's not very 29 The PSU consists in two PCBs coupled with long jumpers. It's not very
30 difficult to disassemble them but not that straighforard either. I've 30 difficult to disassemble them but not that straighforard either. I've
31 seen easier test equipments to take apart. 31 seen easier test equipments to take apart.
32 32
33 Whatever, its problem was a classic failure of several X2 and Y 33 Whatever, its problem was a classic failure of several X2 and Y
34 capacitors on the regulator board (A2): 34 capacitors on the regulator board (A2):
35 35
36 .. image:: {static}images/tek2445/PSU_A2.png 36 .. image:: {static}/images/tek2445/PSU_A2.png
37 :alt: The regulator board os the PSU. 37 :alt: The regulator board os the PSU.
38 38
39 .. image:: {static}images/tek2445/board_a2.jpg 39 .. image:: {static}/images/tek2445/board_a2.jpg
40 :alt: The regulator board os the PSU. 40 :alt: The regulator board os the PSU.
41 41
42 .. image:: {static}images/tek2445/board_a2_C1018.jpg 42 .. image:: {static}/images/tek2445/board_a2_C1018.jpg
43 :alt: Dead C1018 capacitor. 43 :alt: Dead C1018 capacitor.
44 44
45 45
46 and the inverter board (A3), mainly C1020, C1051 and C1052: 46 and the inverter board (A3), mainly C1020, C1051 and C1052:
47 47
48 .. image:: {static}images/tek2445/PSU_A3.png 48 .. image:: {static}/images/tek2445/PSU_A3.png
49 :alt: The inverter board of the PSU. 49 :alt: The inverter board of the PSU.
50 50
51 51
52 For now, I've replaced them with parts from old switching power 52 For now, I've replaced them with parts from old switching power
53 supplies (from old Dell and IBM computers), but I'd rather replace 53 supplies (from old Dell and IBM computers), but I'd rather replace
54 them with brand new components. I also still have some small display 54 them with brand new components. I also still have some small display
55 instabilities, which I need to investigate a bit more. I'll probably 55 instabilities, which I need to investigate a bit more. I'll probably
56 replace most of the electrolytics caps on the PSU so that I won't have 56 replace most of the electrolytics caps on the PSU so that I won't have
57 to repair again any time soon (famous last words). 57 to repair again any time soon (famous last words).
58
59

mercurial