Mon, 17 Dec 2007 18:59:45 +0100
some forgotten added files
""" HP3562A ======= Module for communicating with the HP 3562A Digital Signal Analyzer. Subpackages ----------- Constants --------- """ from gpib import gpib ##################### # HP3562A constants # GPIB buffer size is 3x80 characters lines class STATUS_BYTE(gpib.Constants): # HP3562A Status Byte, as returned by a serial poll _constants = [(0x40, "RQS", "Request Service"), # when sent in response to a serial poll (0x20, "ERR", "GPIB error"), (0x10, "RDY", "ready to accept GPIB commands"), ] conditions = [(0, "NSR", "No service requested"), (1, "USRQ1", "User SRQ #1"), (2, "USRQ1", "User SRQ #2"), (3, "USRQ1", "User SRQ #3"), (4, "USRQ1", "User SRQ #4"), (5, "USRQ1", "User SRQ #5"), (6, "USRQ1", "User SRQ #6"), (7, "USRQ1", "User SRQ #7"), (8, "USRQ1", "User SRQ #8"), (9, "EOD", "End of disk action"), (10, "EOP", "End of plot action"), (11, "STCH", "Instrument status changed"), # any change in # the status register sets this condition (12, "PWR", "Power on"), (13, "KEY", "Key pressed"), (14, "DCP", "Device clear plotter (listen)"), # ... ] def __init__(self): super(STATUS_BYTE, self).__init__() self._conditions = dict([(x[0], x[1]) for x in self.conditions]) self._rev_conditions = dict([(x[1], x[0]) for x in self.conditions]) self._long_conditions = dict([(x[0], x[2]) for x in self.conditions]) def byte_condition(self, byte): byte = byte & 0x8F return self._conditions.get(byte, "N/A") class IS_REGISTER(gpib.Constants): _constants = [(0x01, "MEASP", "measeurement pause"), (0x02, "ASQP", "Auto sequence pause"), (0X04, "EOM", "End of measurement, capture or throughput"), (0x08, "EOAS", "End of auto sequence"), (0x10, "SWPR", "Sweep point ready"), (0x20, "CH1OV", "Channel 1 overrange"), (0x40, "CH2OV", "Channel 2 overrange"), (0X80, "CH1HR", "Channel 1 half range"), (0x100, "CH2HR", "Channel 2 half range"), (0x200, "SFALT", "Source falt"), (0x400, "RUNL", "Reference unlock"), (0x800, "RMKT", "Remote marker knob turn"), (0x1000, "REKT", "Remote entry knob turn"), (0x2000, "ASRC", "Asctive Status Register changed"), (0x4000, "PWRF", "Power-on test failed"), ] class StatusQuery(gpib.Constants): _command = "STA?" _constants = [(0x01, "N/A", "Not used"), (0x02, "N/A", "Not used"), (0x04, "KEY", "Key pressed"), (0x08, "N/A", "Not used"), (0x10, "RDY", "Ready"), (0x20, "ERR", "Error"), (0x40, "RQS", "Request"), (0x80, "MOS", "Message on screen"), (0x100, "MEASP", "measeurement pause"), (0x200, "ASQP", "Auto sequence pause"), (0X400, "EOM", "End of measurement, capture or throughput"), (0x800, "EOAS", "End of auto sequence"), (0x1000, "SWPR", "Sweep point ready"), (0x2000, "CH1OV", "Channel 1 overrange"), (0x4000, "CH2OV", "Channel 2 overrange"), (0x8000, "MAOV", "Math overflow"), ] class ActivityStatysRegister(gpib.Constants): _command = "AS?" _constants = [(0x01, "CKFL", "Check fault log"), (0x02, "FITR", "Filling time record"), (0x04, "FLTR", "Filters settings"), (0x08, "CFTP", "Curve fir in progress"), (0x10, "MSSM", "Missed sample"), (0x20, "TMPR", "Timed preview"), (0x40, "ACDA", "Accept date"), #... ]